Represents the combined voltage-and-current capacity of the electrical system without converting it to useful real power.
kW vs kVA
Understand what each rating means, how power factor changes the relationship, and why two generators with the same kVA can still be different buying decisions.
kVA IS APPARENT POWER. kW IS REAL POWER.
For generator buying, both numbers matter because the alternator and engine are not being described in exactly the same way.
Represents the portion of electrical power that can perform useful work at the stated power factor.
Describes the relationship between real power and apparent power. It is part of the comparison basis, not a decorative number.
0.8 POWER FACTOR IS A COMMON GENERATOR RATING BASIS — NOT A UNIVERSAL LOAD CONDITION.
A generator nameplate may use 0.8 PF as its rating convention, while the actual connected load behaves differently.
THE EQUATION CHANGES WITH THE POWER FACTOR.
Unity power factor means all apparent power is converted to real power.
This is the common generator example most buyers recognize.
The same kVA now corresponds to less real power.
THE LOAD CAN CHANGE THE ELECTRICAL BEHAVIOR.
Power factor is not the only issue. Starting current, harmonics and transient behavior also affect generator selection.
ONE RATING INVOLVES TWO DIFFERENT LIMITS.
A genset has a mechanical prime mover and an electrical alternator. A complete comparison checks whether both are appropriately matched.
The engine must provide enough mechanical power for the required real electrical output after system losses.
The alternator must carry the required current and manage voltage regulation, temperature rise and load characteristics.
A generator set should be evaluated as a matched system under the intended duty and site condition.
DO NOT LET “100 kVA” END THE TECHNICAL REVIEW.
WHERE kW / kVA COMPARISONS GO WRONG.
That is only true at power factor 1.0.
The genset rating convention and the actual site load are not the same thing.
A standby rating and a prime rating should not be treated as equivalent.
Running kW alone may not show the transient requirement.
High temperature and altitude can reduce usable output.
Engine, alternator and test basis still need to be checked.
THE NUMBER IS ONLY USEFUL WHEN THE CONDITIONS BEHIND IT ARE CLEAR.
For procurement, kW and kVA should be treated as part of a rating system rather than as isolated numbers. The useful question is not only “what is the rating?” but also “under what power factor, duty and site condition?”
MFG POWER compares the rating basis together with the engine, alternator, load type and test condition before treating two offers as equivalent.
CHECK THE RATING BASIS BEFORE YOU COMPARE THE PRICE.
Send the quotation, datasheet or load requirement. MFG POWER can help identify whether the kW/kVA, duty, power factor and component basis are actually comparable.
Review my generator rating